- Contact Person : Mr. ke genyou
- Company Name : Jinhua Huiyou Equipment And Instrument Co., Ltd.
- Tel : 86-579-83202038
- Fax : 86-579-82343786
- Address : Zhejiang,jinhua,Room 406, No.737 Renmin Road,Jinhua City
- Country/Region : China
HY 3060 Cryostat microtome
Features: 1.The HY-3060 has been designed with all ergonomic considerations in mind. All the components are processed with computer controlled numerical machining centers 2.The specimen retraction function, protects the specimen from blade damage. 3. Electronic Trim/Cut function makes it easy to switch from trim and section mode 4.The HY-3060 is equipped with a rotation counter function in order to calculate total section pieces and total thickness. 5.The refrigeration system contains one compressor, which is made in , and freezes the cryostat chamber and shelf separate with environmentally safe refrigerant (R404) 6.The chamber temperature can drop to working condition within 60 minutes after switching the unit on. 7.Sterilization can be accomplished with UV light within 35 minutes after use. 8.Peltier may be switched on or off manually. 9.Unit contains heated, removable sliding window. 10.Unit contains two defrost methods: definite time and manual 11.The high-precision microtome is enclosed outside the cryostat chamber to protect it from thermal expansion and contraction and keep minimum service and maintenance. 12.Self-explanatory symbols for all functions and displays make the unit easy to learn and operate. 13.LED screen can display data such as sample travel, thickness, function control, day, time, temperature and time on/off. 14.Stand by mode, after initialization, the temperature in cryostat chamber can be controlled between -4°C an -9°C by computer automatically; once stopped initializing, the temperature in freeze chamber will arrive to working temperature within 10 minutes 15.Control panel with locking function to avoid improper operation. 16.Specimen orientation on X/Y axes 8°and specimen rotation on Z axes 360° Technical Specifications 1.Freeze chamber temperature rage :-10°C~-30°C 2.Cooling down time to -30°C:60 min 3.Freeze shelf minimum temperature:-45°C 4.Lowest temperature of Peltier unit on freeze shelf:-55°C 5.Peltier working time: 15 minutes 6.Maximum specimen size:35mm×35mm 7.Specimen vertical stroke:60mm 8.Specimen horizontal stroke:20mm 9.Coarse feeding speed: 0.7mm/s; 0.35mm/s 10.Section thickness range: 1μm~80μm adjustable; 1μm~20μm, in 1μm increment 20μm~40μm, in 2μm increments; 40μm~80μm, in 5μm increments 11.Trimming thickness range:10μm~400μm adjustable; 10μm~50μm, in 5μm increments; 50μm~100μm, in 10μm increments; 100μm~400μm, in 50μm increments; 12.Retraction range: 0μm~80μm adjustable; in 5μm increment 13.Voltage and frequency:AC220V±10% 50Hz .Special requirement may customize by order. 14.Power:650W 15.Weight:125kg 16.Dimensions(W×D×H):660×640×1130mm |
HY 3060 Cryostat microtome